Home > Resource Center > FAQs > Why should I optimize my ASD spectrometer?
 

ASD

  • Our blog
  • Contact Us
  • facebook
  • linked in
  • youtube
  • Products
    • FieldSpec

      • FieldSpec 4

        • FieldSpec 4 Standard-Res Spectroradiometer
        • FieldSpec 4 Hi-Res Spectroradiometer
        • FieldSpec 4 Wide-Res Spectroradiometer
      • FieldSpec 3

        • FieldSpec 3 Portable Spectroradiometer
        • FieldSpec 3 Hi-Res Portable Spectroradiometer
        • FieldSpec 3 Max Portable Spectroradiometer
        • HandHeld 2 Portable Spectroradiometer
    • TerraSpec

        • TerraSpec 4 Standard-Res Mineral Analyzer
        • TerraSpec 4 Hi-Res Mineral Spectrometer
    • QualitySpec

        • QualitySpec 7000
    • LabSpec

        • LabSpec 4 Standard-Res Lab Analyzer
        • LabSpec 4 Hi-Res Analytical Instrument
        • LabSpec 4 Bench Benchtop Analyzer
    • Software

      • ASD Software

        • Indico Pro Spectral Acquisition Software
        • RS3 Spectral Acquisition Software
      • Third-party Software

        • GRAMS Suite
        • KaleidaGraph
        • TSG Pro
        • TSG Pro Add-On Packages
        • Spectral Analysis Processing Program
        • The Unscrambler
      • Accessories

        Products
      • Applications
        • Remote Sensing

            • Field Spectroscopy
            • Ground Truthing
            • Spectral Remote Sensing
            • Crops and Soils Research
            • Ice Research and Snow Research
            • Landscape Ecology and Ecology Research
            • See more Remote Sensing
        • Mining

            • Mining Exploration
            • Mining Production
            • Extractive Metallurgy
            • See more Mining
        • Additional

            • Agriculture and Soil Analysis
            • Raw Material Inspection and Analysis
            • Forest Products
            • Pharmaceutical
            • Optics and Photonics
            • See more Additional
        Applications
      • Service and Support
        • SummitCAL
        • Instrument Service
        • Training
        • Technical Support
        • Goetz Instrument Program
         
        Service and Support
      • Events
        • ASD Events
        • Partner Events
        • Training
        • Events
        Events
      • Resource Center
        • FAQs
        • Application Notes
        • Documents
         
        Resource Center
      • About Us
        • News
        • Careers
        • About Our Experts
        • Milestones
        • History of ASD
        • Management Team
        • Corporate Citizenship
        • Partners and Memberships
        • Why NIR
         
        About Us
      Resource Center
      Resource Center
        • FAQs
        • Application Notes
        • Documents
          • Accessories
          • FieldSpec
          • SummitCAL
          • TerraSpec
          • FieldSpec Advisor Newsletter

      FAQs

    • Measurement Terminology
    • NIR Terminology
    • Instrument Use
    • Why should I optimize my ASD spectrometer?

      Optimizing your ASD spectrometer results in:

      • Automatic setting of Gains and Offsets for the Swir detectors
      • Automatic setting of Integration Time value for Vnir detector
      • Automatic Dark Current collect

      Optimization values depend on the response to light in a particular spectral region. A well-optimized instrument will display between 20 and 35 thousand DN (approx.), if the source is within the Gain and Integration time abilities of the system.

      A Spectralon blank should be used when optimizing and for taking a white reference measurement. An Optimization is required before any data is acquired.

      The instrument must be re-optimized after any change in temperature - internal or environmental - or lighting conditions . If lighting conditions don't change at all, the Gain won't change significantly from the value after optimization; but Offset, even if it changes by 10 (say from 2150 to 2160), will have a significant effect if Gain is relatively high, like around 25. The SWIR 2 dark current increases with temperature and dramatically reduces the dynamic range of the spectrometer. Note that conditions can change rapidly or slowly, it all depends on clouds, wind (affecting temperature), instrument warm up time, etc. 

      Back to List
      • Contact Us
      • Find a Representative
      • Join our NIR Community

      Products

      • FieldSpec
      • TerraSpec
      • QualitySpec
      • LabSpec
      • Software
      • Spectroscopy Accessories

      Applications

      • Remote Sensing
      • Mining
      • Additional

      Service and Support

      • SummitCAL
      • Instrument Service
      • Training
      • Technical Support
      • Goetz Instrument Program

      Events

      Resource Center

      • FAQs
      • Application Notes
      • Documents

      About Us

      • News
      • Careers
      • About Our Experts
      • Milestones
      • History of ASD
      • Management Team
      • Corporate Citizenship
      • Partners and Memberships
      • Why NIR

      Copyright 2011 by ASD Inc. Terms & Conditions | Privacy Policy | Site Map | Support

      Connect with ASD Inc.: www.facebook.com www.youtube.com