Home > Resource Center > FAQs > Why should I optimize my ASD spectrometer?
 

ASD

  • Our blog
  • Contact Us
  • facebook
  • linked in
  • youtube
  • Products
    • FieldSpec

      • FieldSpec 4

        • FieldSpec 4 Standard-Res Spectroradiometer
        • FieldSpec 4 Hi-Res Spectroradiometer
        • FieldSpec 4 Wide-Res Spectroradiometer
      • FieldSpec 3

        • FieldSpec 3 Portable Spectroradiometer
        • FieldSpec 3 Hi-Res Portable Spectroradiometer
        • FieldSpec 3 Max Portable Spectroradiometer
        • HandHeld 2 Portable Spectroradiometer
    • TerraSpec

        • TerraSpec 4 Standard-Res Mineral Analyzer
        • TerraSpec 4 Hi-Res Mineral Spectrometer
    • QualitySpec

        • QualitySpec Pro Vis/NIR Spectrometer
        • QualitySpec 7000
    • LabSpec

      • LabSpec

        • LabSpec 2500/2600 Portable Vis/NIR Spectrometer
        • LabSpec 5000/5100 Portable Lab Instrument
      • Software

        • ASD Software

          • Indico Pro Spectral Acquisition Software
          • RS3 Spectral Acquisition Software
        • Third-party Software

          • GRAMS Suite
          • KaleidaGraph
          • The Unscrambler
        • Accessories

          Products
        • Applications
          • Remote Sensing

              • Field Spectroscopy
              • Ground Truthing
              • Spectral Remote Sensing
              • Crops and Soils Research
              • Ice Research and Snow Research
              • Landscape Ecology and Ecology Research
              • See more Remote Sensing
          • Mining

              • Mining Exploration
              • Mining Production
              • Extractive Metallurgy
              • See more Mining
          • Additional

              • Agriculture and Soil Analysis
              • Raw Material Inspection and Analysis
              • Forest Products
              • Pharmaceutical
              • Optics and Photonics
              • See more Additional
          Applications
        • Service and Support
          • SummitCAL
          • Instrument Service
          • Training
          • Technical Support
          • Goetz Instrument Program
           
          Service and Support
        • Events
          • ASD Events
          • Training
          Events
        • Resource Center
          • FAQs
          • Application Notes
           
          Resource Center
        • About Us
          • News
          • Careers
          • About Our Experts
          • Milestones
          • History of ASD
          • Management Team
          • Corporate Citizenship
          • Partners and Memberships
          • Why NIR
           
          About Us
        Resource Center
        Resource Center
          • FAQs
          • Application Notes

        FAQs

      • Measurement Terminology
      • NIR Terminology
      • Instrument Use
      • Why should I optimize my ASD spectrometer?

        Optimizing your ASD spectrometer results in:

        • Automatic setting of Gains and Offsets for the Swir detectors
        • Automatic setting of Integration Time value for Vnir detector
        • Automatic Dark Current collect

        Optimization values depend on the response to light in a particular spectral region. A well-optimized instrument will display between 20 and 35 thousand DN (approx.), if the source is within the Gain and Integration time abilities of the system.

        A Spectralon blank should be used when optimizing and for taking a white reference measurement. An Optimization is required before any data is acquired.

        The instrument must be re-optimized after any change in temperature - internal or environmental - or lighting conditions . If lighting conditions don't change at all, the Gain won't change significantly from the value after optimization; but Offset, even if it changes by 10 (say from 2150 to 2160), will have a significant effect if Gain is relatively high, like around 25. The SWIR 2 dark current increases with temperature and dramatically reduces the dynamic range of the spectrometer. Note that conditions can change rapidly or slowly, it all depends on clouds, wind (affecting temperature), instrument warm up time, etc. 

        Back to List
        • Contact Us
        • Find a Representative
        • Join our NIR Community

        Products

        • FieldSpec
        • TerraSpec
        • QualitySpec
        • LabSpec
        • Software
        • Spectroscopy Accessories

        Applications

        • Remote Sensing
        • Mining
        • Additional

        Service and Support

        • SummitCAL
        • Instrument Service
        • Training
        • Technical Support
        • Goetz Instrument Program

        Events

        Resource Center

        • FAQs
        • Application Notes

        About Us

        • News
        • Careers
        • About Our Experts
        • Milestones
        • History of ASD
        • Management Team
        • Corporate Citizenship
        • Partners and Memberships
        • Why NIR

        Copyright 2011 by ASD Inc. Terms & Conditions | Privacy Policy | Site Map | Support

        Connect with ASD Inc.: www.facebook.com www.youtube.com